Temperature Scales Conversion
Relation between Celsius, Fahrenheit and Kelvin readings, and the general form for any scale X with its own lower (LFP) and upper (UFP) fixed points.
Thermal properties of matter covering temperature scales, thermal expansion of solids and liquids, calorimetry, specific and latent heat, and conduction through composite rods and slabs.
Relation between Celsius, Fahrenheit and Kelvin readings, and the general form for any scale X with its own lower (LFP) and upper (UFP) fixed points.
Thermal expansion for small temperature change DeltaT, with beta = 2 alpha and gamma = 3 alpha for isotropic solids; density falls as volume rises.
Real coefficient of volume expansion of a liquid equals the apparent one (seen in a vessel) plus that of the vessel; overflow volume depends on the apparent coefficient.
Radius of curvature R of a bimetallic strip heated by DeltaT, where d is the separation between the mid-lines of the strips (equal to one strip thickness for equal thicknesses) and alpha_2 > alpha_1.
Fractional change in time period of a pendulum clock when its rod expands, and the condition that two rods of lengths L1 and L2 keep a constant difference in length at all temperatures.
Water contracts when heated from 0 to 4 degrees C, so its density is maximum and its volume minimum at 4 degrees C; above this it expands normally.
Heat absorbed or released by a body of mass m and specific heat c; heat capacity is C_body = mc and water equivalent is the mass of water with the same heat capacity.
Final equilibrium temperature of two substances mixed without phase change or heat loss, and effective specific heat of the mixture.
Heat for a phase change at constant temperature, standard latent heats of water (NCERT values), and the energy balance when ice at 0 degrees C melts completely in warm water at T_w to give a final temperature T.
Steady-state heat current through a slab or rod of length L, cross-section A and conductivity k; the thermal resistance is analogous to electrical resistance with temperature difference as potential difference.
Equivalent conductivity of rods of the same cross-section joined end to end (series) or side by side (parallel), and the junction temperature T_int in steady-state series conduction with end temperatures T1 and T2.
Time for an ice layer of thickness x to form on still water when the air above is at temperature -theta (surface at -theta, water at 0 degrees C), with rho the density of ice, L_f latent heat of fusion and k conductivity of ice.
Frequently tested misconceptions in Thermal Properties & Calorimetry